• Johor Bahru Office 44 & 44A, Jalan Palma Rafis 1, Taman Dato Chellam, 81800 Ulu Tiram, Johor, Malaysia.
  • Call us +607-8660510
  • Email us enquiry@saturnpyro.com
Voltage DetectorsInsulation PolesEarthing and Short-Curcuit EquipmentInsulationPersonal Protection EquipmentLockout & Tagout (LOTO)First Aid and PreventionLadderDisplayARC Flash Protection Suits Arc Flash Suit Fibre Glass Ladders & Work PlatformsSignalizationUlirvision - Thermal Monitoring System Others

Saturn Pyro Sdn Bhd
44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8660510
+607-8660511

Saturn Pyro Sdn Bhd
Johor Bahru Office
44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8660510
+607-8660511
enquiry@saturnpyro.com
 
Shah Alam Office
K03-03-12, Tower 3,
UOA Business Park,
No 1, Jalan
Pengaturcara U1/51A,
Section U1, Kawasan
Perindustrian Temasya,
40150 Shah Alam,
Selangor, Malaysia.
+607-8660510
+607-8660511
Penang Office
Penthouse 1-21-1,
Suntech @ Penang Cybercity
Lintang Mayang Pasir 3,
11950 Bayan Baru,
Penang, Malaysia.
+607-8660510
+607-8660511
desmond@saturnpyro.com

Bangalore Office
Saturnpyro Solutions Pvt. Ltd.

SFS-B-38, 1st Floor, 7th B Main Road,
Yelahanka New Town, Bangalore 560 064.
GSTIN: 29ABCCS4606C1ZK
+91 829 192 0602
+601 7488 7001
 
India Office
3, Gr Floor, Eishita,
Shiv Vallabh Cross Road,
Ashokvan, Dahisar (E.),
Mumbai 400068.
+91 22284 84682
+91 98191 56654


647 VTC-OAD

Previous 1 / 6 Next

647 VTC-OAD Voltage Detectors for Catenary Lines Voltage Detectors 647 VTC-OAD Voltage Detectors for Catenary Lines Voltage Detectors 647 VTC-OAD Voltage Detectors for Catenary Lines Voltage Detectors


Download Files

INSTRUCTIONS_FOR_USE.pdf (454.03 KB)
CATALOG_INFORMATION.pdf (1.79 MB)
DC voltage detector with AC induced voltage indication / Optical & Acoustic
 
Field of application: To be used in DC voltage electrical systems of up to 5000 DC, where there are adjacent AC systems of up to 25 kVA, not to be used in installations with only alternating current service voltage.
Working voltage range: Direct current: 500 V < Vtdc < 5000 V
AC induced voltage: 500 V < Vtac < 5000 V
Usage frequency: DIRECT current
ALTERNATING current 50-60 Hz
Operating Temperature: -25°C to 55°C
Humidity range: 20 to 96 %. Not apt for use in rainfall.
Indication of alert status: By means of high luminosity green LED light. There is no voltage or it is below the detection thresholds.
Voltage presence indication: Optical: fixed orange LED light when DC voltage presence.
Flashing red LED light when AC induced voltage presence.
Acoustic: Fixed buzzer when DC voltage presence. Alternated buzzer when AC voltage presence.
Battery: 9 V, type 6LR61.
Low battery indication by flashing green LED light and off when battery level is critical.
Ground cable: Extra flexible cable with silicon sheath and 6m length (possibility of other lengths at customer’s request).
Insulation pole: With universal head.
Self-checking: Full self-checking system with automatic disconnection after 2 minutes. WITHOUT DETECTION.
Automatic start-up: Automatic start-up system using detection of voltage (approx. 400 Vdc).
Electrode: Non-exchangeable. L type (without contact electrode extension).
Threshold voltage: Between 350 - 490 V

Specifications