• Johor Bahru Office 44 & 44A, Jalan Palma Rafis 1, Taman Dato Chellam, 81800 Ulu Tiram, Johor, Malaysia.
  • Call us +607-8660510
  • Email us enquiry@saturnpyro.com
Voltage DetectorsInsulation PolesEarthing and Short-Curcuit EquipmentInsulationPersonal Protection EquipmentLockout & Tagout (LOTO)First Aid and PreventionLadderDisplayARC Flash Protection Suits Arc Flash Suit Fibre Glass Ladders & Work PlatformsSignalizationUlirvision - Thermal Monitoring System Others

Saturn Pyro Sdn Bhd
44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8660510
+607-8660511

Saturn Pyro Sdn Bhd
Johor Bahru Office
44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8660510
+607-8660511
enquiry@saturnpyro.com
 
Shah Alam Office
K03-03-12, Tower 3,
UOA Business Park,
No 1, Jalan
Pengaturcara U1/51A,
Section U1, Kawasan
Perindustrian Temasya,
40150 Shah Alam,
Selangor, Malaysia.
+607-8660510
+607-8660511
Penang Office
Penthouse 1-21-1,
Suntech @ Penang Cybercity
Lintang Mayang Pasir 3,
11950 Bayan Baru,
Penang, Malaysia.
+607-8660510
+607-8660511
desmond@saturnpyro.com

Bangalore Office
Saturnpyro Solutions Pvt. Ltd.

SFS-B-38, 1st Floor, 7th B Main Road,
Yelahanka New Town, Bangalore 560 064.
GSTIN: 29ABCCS4606C1ZK
+91 829 192 0602
+601 7488 7001
 
India Office
3, Gr Floor, Eishita,
Shiv Vallabh Cross Road,
Ashokvan, Dahisar (E.),
Mumbai 400068.
+91 22284 84682
+91 98191 56654


647 VTC-OA

Previous 2 / 6 Next

647 VTC-OA Voltage Detectors for Catenary Lines Voltage Detectors 647 VTC-OA Voltage Detectors for Catenary Lines Voltage Detectors 647 VTC-OA Voltage Detectors for Catenary Lines Voltage Detectors


Download Files

INSTRUCTIONS_FOR_USE.pdf (3.82 MB)
CATALOG_INFORMATION.pdf (1.38 MB)
DC voltage detector / Optical & Acoustic
 
Voltage range: 500 V < Vt < 5000 V
Usage frequency: DIRECT current
Operating temperature: -25°C to 55°C
Humidity Range: 20 to 96 %
Indication of alert status: Through high luminosity green LED.
There is no voltage or it is below the established detection threshold.
Indication of voltage presence: Optical/Acoustic indication through high luminosity red LED and high pressure acoustic buzzer*
Battery: 9 V battery, type 6LR61
Low battery indication by flashing green LED, when battery level is critical green led is off.
Earthing cable: Extra flexible cable with silicon sheath and 6m long (possibility of other lengths at customer’s request)
Isulating pole: With universal head
Self-checking: Full self-checking system with automatic disconnection after two minutes WITHOUT DETECTION.
Automatic start-up: Automatic start-up system using detection of voltage (approx. 400V dc)
Electrode: Possibility of exchanging electrode
Threshold voltage: Threshold 1 - From 350 to 490 V: Red led
Threshold 2 - From 900 to 1100 V: Red and orange led

Specifications



Switch to Mobile Version